Remko WPM-Smart-Control-Manual for specialists-WKF-085 Manual de usuario Pagina 28

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 84
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 27
Circulation type
(dependent on which probes are used)
Impulse circulation:
If briefly dispensing water triggers an impulse on
the flow-operated safety device, this is registered
by the controller and the circulation pump is started
up. This means that the circulation is also active
when it is required.
Temperature-guided circulation:
Temperature-guided circulation keeps the hot
water temperature at the set temperature.
Select the circulation type with the rotary knob,
then confirm the entry with "OK".
Fig. 42: Selecting the circulation type
Menu item Parameter Factory setting
Circulation
type
Impulse
circulation
As required
Temperature-
guided circula-
tion
Press "Next".
Impulse-guided circulation -
Running time of the circulation
Switch-on time of the circulation pump after a dis-
pensing impulse.
If the circulation line is very short, a shorter running
time may suffice. If the time is not sufficient to
pump hot water to a remote dispensing point, the
running time must be extended.
To set the desired temperature, select it with the
rotary knob and confirm the entry with "OK".
Fig. 43: Impulse-guided circulation - Selecting the
running time of the circulation
Menu item Parameter Factory setting
Impulse-
guided circu-
lation - Run-
ning time of
the circula-
tion
1 min - 15 mins 5 mins
Press "Next".
REMKO Smart WP MANAGER
28
Vista de pagina 27
1 2 ... 23 24 25 26 27 28 29 30 31 32 33 ... 83 84

Comentarios a estos manuales

Sin comentarios