Operating manual
Read the instructions prior to performing any task!
REMKO Smart WP MANAGER
Smart-Control for WKF/WKF-compact 85/120/180
Manual for experienced specialists
0032-2012-09 Edition 1, en_GB
Vista de pagina 0
1 2 3 4 5 6 ... 83 84

Indice de contenidos

Pagina 1 - Operating manual

Operating manualRead the instructions prior to performing any task!REMKO Smart WP MANAGERSmart-Control for WKF/WKF-compact 85/120/180Manual for experi

Pagina 2 - Made by REMKO

3 Operation - User level 3.1 Menu structure of the con-troller The following information is primarily directed atsystem operators. Specialists

Pagina 3 - Table of contents

Overview of the menus (User level)LEVEL 03D houseHot waterRoom climateLEVEL 1Information Settings MessagesLEVEL 2BasicinformationSolarBasicsettingsSol

Pagina 4

"3D house" animationOnce the Smart-Control commissioning wizard hasbeen completed, you will see the home screen withthe 3D house. Pressing t

Pagina 5

Explanation of operating modes:Standby - the controller waits for the next requestDispensing operation - hot water is being dis-pensedCirculation - ci

Pagina 6

Favourites menu: for the userUsing the rotary knob (turning it clockwise) you canaccess other views. They allow you to rapidly andeasily adjust the mo

Pagina 7 - Operation - General

One-off hot water / party modeActivating Party mode (select with the rightsoftkey) causes the next window of time withreduced heating to be disregarde

Pagina 8

CO2 savingsCO2 savings specifies how much CO2 emissionshave been avoided. The calculation of CO2 savingsis based on the amount of renewable energy gen

Pagina 9 - Next viewStart animation

"Information" menu item - UserThis menu contains information about the current operating status of the system. The menu is opened withthe

Pagina 10 - REMKO Smart WP MANAGER

"Information" menu item (continued) - UserAuthorisa-tion levelLevel 2menu itemLevel 3 menu item InfoSolarPump A01 / Pump control signal A4

Pagina 11 - Aditional

"Information" menu item (continued) - UserAuthorisa-tion levelLevel 2 menuitemLevel 3 menu item InfoFloorheating cycleAbs.prim. pump speed

Pagina 12

Made by REMKOTranslation of the original operating manualRead these operating instructions carefully before commis-sioning / using this device!These

Pagina 13

"Information" menu item (continued) - UserAuthorisa-tion levelLevel 2 menuitemLevel 3 menu item InfoHeat pumpHeat pump statusYou can findm

Pagina 14

"Settings" menu item - UserIn this menu you can configure the settings. For example, you can adjust hot water and heating tempera-tures or

Pagina 15 - Time period

"Settings" menu item (continued) - UserAuthorisa-tion levelLevel 2 menuitemLevel 3 menu item Level 4 menu item InfoHeating /coolingModeRoo

Pagina 16

4 Operation - Expert level 4.1 Commissioning wizard The commissioning wizard which starts when thecontroller is activated is intended for pro

Pagina 17

Setting the countrySelect the country with the rotary knob and confirmthe entry with "OK".Fig. 30: Selecting a countryMenu item ParameterFac

Pagina 18

Menu item ParameterFactorysettingNederlandsPolskiPress "Next".Setting the time zone for the winter timeSelecting the time zone for the winte

Pagina 19

Activating the heat pumpThe controller detects automatically that a heatpump has been connected. If necessary, activatethe heat pump (select with the

Pagina 20

ReheatingDesired charging temperature for the hot waterstorage tank.Set temperature to which conventional reheatingshould heat the storage tank to ens

Pagina 21

Circulation type(dependent on which probes are used)Impulse circulation:If briefly dispensing water triggers an impulse onthe flow-operated safety dev

Pagina 22

Impulse-guided circulation - Disable switch-onAfter the running time of the circulation pump, thepump cannot be started again while disable switchon i

Pagina 23 - Operation - Expert level

Table of contents1 Safety and usage instructions...

Pagina 24

Heating-curve heating cycle modeThe heating curve can be adjusted in three points,according to the structure and location-related con-ditions of the b

Pagina 25

System separationActivation if the floor heating cycle is separated bya heat exchanger.To control a separate heating cycle pump with asystem separatio

Pagina 26

Standard inlet temperature:the standard inlet temperature corresponds to theset temperature of the heating water at thestandard outside temperature in

Pagina 27

BuildingtypeHeat retention abilityRecom-mended valueLight Low heat retention ability, e.g. prefab / wood-frame houses approx. 10hMedium Moderate heat

Pagina 28

Cooling functionActivate (select with the rotary knob and confirmwith "OK") if the building is to be actively cooledwith the heat pump in su

Pagina 29

Menu item Parameter Factory settingPump type(solar cycle)AsynchronouspumpEC pumpSelectionaccording topump typeinstalled in thesolar cycleSolar speed c

Pagina 30

Setting the impulse rate of the solar mediumflow rate probeThe impulse rate may only be changed (select withthe rotary knob and confirm with "OK&

Pagina 31

Set temperature of the storage tank duringsolar chargingOnce the solar set temperature is reached, thesolar cycle pump is switched off. With the colle

Pagina 32

4.2 Template hydraulic diagrams with installation parameters NOTICE!The following template hydraulic systems are only to be used as a planning aid

Pagina 33

Menu item Parameter Factory settingControl panel address Control panel 1-3 Control panel 1Country Deutschland - Slovensko DeutschlandLoad setting Acce

Pagina 34

1 Safety and usageinstructions 1.1 General safety notes Carefully read the operating manual before com-missioning the units for the first time.

Pagina 35

Menu item Parameter Factory settingCooling function Activated / Deactivated Deactivated / Enable as requiredSeparate cooling cycle Activated / Deactiv

Pagina 36

Hydraulic diagram for heat pump assembly WKF FrankfurtFunctions: heating and hot water, operating mode: monoenergetic or bivalent alternative. Solar p

Pagina 37

Menu item Parameter Factory settingCirculation running time 1 min - 15 mins 5 minsDisable switch-on 1 min - 15 mins 5 minsCirculation type Impulse or

Pagina 38

Hydraulic diagram for heat pump assembly WKF Dortmund 2Functions: heating or cooling and hot water, operating mode: monoenergetic.Only one cycle is po

Pagina 39

Menu item Parameter Factory settingCirculation running time 1 min - 15 mins 5 minsDisable switch-on 1 min - 15 mins 5 minsCirculation type Impulse or

Pagina 40

Hydraulic diagram for heat pump assembly WKF compact StuttgartFunctions: heating or cooling and hot water, operating mode: monoenergetic.Only one cycl

Pagina 41

Menu item Parameter Factory settingCirculation type Impulse or Temperature ImpulseCirculation running time 1 min - 15 mins 5 minsDisable switch-on 1 m

Pagina 42

Hydraulic diagram for heat pump assembly WKF compact Mannheim bivalentFunctions: heating or cooling and hot water, operating mode: monoenergetic or bi

Pagina 43

Menu item Parameter Factory settingCirculation type Impulse or Temperature ImpulseCirculation running time 1 min - 15 mins 5 minsDisable switch-on 1 m

Pagina 44

Hydraulic diagram for heat pump assembly WKF Düsseldorf 2Functions: heating or cooling and hot water, operating mode: monoenergetic.Only one cycle is

Pagina 45

1.6 Safety notes for the operator The operational safety of the units and compo-nents is only assured providing they are used asintended and in a f

Pagina 46

Menu item Parameter Factory settingCirculation running time 1 min - 15 mins 5 minsDisable switch-on 1 min - 15 mins 5 minsCirculation type Impulse or

Pagina 47

Hydraulic diagram for heat pump assembly WKF compact Stuttgart SolarFunctions: heating or cooling/hot water and solar, operating mode: monoenergeticOn

Pagina 48

Menu item Parameter Factory settingCirculation running time 1 min - 15 mins 5 minsDisable switch-on 1 min - 15 mins 5 minsCirculation type Impulse or

Pagina 49

Hydraulic diagram for heat pump assembly WKF Frankfurt SolarFunctions: heating/hot water and solar, operating mode: monoenergetic or bivalent possible

Pagina 50

Menu item Parameter Factory settingCirculation running time 1 min - 15 mins 5 minsDisable switch-on 1 min - 15 mins 5 minsCirculation type Impulse or

Pagina 51 - FBKKKW WW

4.3 Menu structure of the controller "Information" menu item - ExpertThis menu contains information about the current operating status

Pagina 52

"Information" menu item (continued) - ExpertAuthorisa-tion levelLevel 2menu itemLevel 3 menu item InfoSolarPump A01 / Pump control signal

Pagina 53

"Information" menu item (continued) - ExpertAuthorisa-tion levelLevel 2 menuitemLevel 3 menu item InfoFloorheating cycleAbs.prim. pump spe

Pagina 54

"Information" menu item (continued) - ExpertAuthorisa-tion levelLevel 2 menuitemLevel 3 menu item InfoHeat pumpHeat pump statusYou can fin

Pagina 55

"Information" menu item (continued) - ExpertAuthorisa-tion levelLevel 2 menuitemLevel 3 menu item Level 4 menu item InfoMeter read-ingsSol

Pagina 56

1.11 Transport and packaging The devices are supplied in a sturdy shipping con-tainer or inside the heat pump casing. Pleasecheck the equipment imm

Pagina 57

"Information" menu item (continued) - ExpertAuthorisa-tion levelLevel 2 menuitemLevel 3 menu item Level 4 menu item InfoMeter read-ingsHou

Pagina 58

"Information" menu item (continued) - ExpertAuthorisa-tion levelLevel 2 menuitemLevel 3 menu item InfoChecklistCollector temp. S01You can

Pagina 59

"Settings" menu item - ExpertIn this menu you can configure the settings. For example, you can adjust hot water and heating tempera-tures

Pagina 60

"Settings" menu item (continued) - ExpertAuthorisa-tion levelLevel 2 menuitemLevel 3 menu item Level 4 menu item InfoBasic settings System

Pagina 61

"Settings" menu item (continued) - ExpertAuthorisa-tion levelLevel 2 menuitemLevel 3 menu item Level 4 menu item InfoSolarCollectorMax. te

Pagina 62

"Settings" menu item (continued) - ExpertAuthorisa-tion levelLevel 2 menuitemLevel 3 menu item Level 4 menu item InfoHot waterDomestic wat

Pagina 63

"Settings" menu item (continued) - ExpertAuthorisa-tion levelLevel 2 menuitemLevel 3 menu item Level 4 menu item InfoHeating /coolingBuild

Pagina 64

"Settings" menu item (continued) - ExpertAuthorisa-tion levelLevel 2 menuitemLevel 3 menu item InfoSolar heatingMin. pump speedYou can fin

Pagina 65

"Settings" menu item (continued) - ExpertAuthorisa-tion levelLevel 2 menuitemLevel 3 menu item Level 4 menu item InfoHeat pumpBasic settin

Pagina 66

"Messages" menu item - ExpertPressing "OK" (right softkey) takes you to submenus of the menu item "Messages".This is w

Pagina 67

2 Operation - General 2.1 Design and functions Overview of the controls34546712 2Fig. 1: Controls of the Smart-Control1: SD card2: Movement

Pagina 68

"Message" menu item (continued) - ExpertManual mode (relay test) (continued) Parameter Selection parameter Cooling changeover valve Ou

Pagina 69

"Message" menu item (continued) - ExpertManual mode (relay test) (continued) Parameter Selection parameter Panel heating cycle pump st

Pagina 70

"Message" menu item (continued) - ExpertManual mode (probes) (continued) Parameter Selection parameter Circulation paddle switch Probe

Pagina 71

"Message" menu item (continued) - ExpertManual mode (probes) (continued) Parameter Selection parameter Solar cycle return temp. Probe

Pagina 72

5 Installation 5.1 Room installation of theSmart-Control NOTICE!Only use the unit in dry areas and protect itfrom electromagnetic radiation.The

Pagina 73

6 Electrical wiring 6.1 Structure electrical connection I/0 module Cable cross-sections corresponding to the supplied connection cable!Place the

Pagina 74

6.2 Terminal assignment / legend Terminal assignmentTerminal Input Output Signal Connection layoutPW X Power supply I/O 230VPP X Power supp

Pagina 75 - Electrical wiring

Terminal Input Output Signal Connection layoutA11 X Changeover valve 2. heat generatorA12 X Changeover valve solar / 2. storage tank poolA13

Pagina 76

7 PV power utilisation 7.1 Higher energy consumptionfrom the combination of heatpump and PV plant Ideal for new and existing photovoltaic plants

Pagina 77

7.2 Using the PV power surplus The self-generated photovoltaic power is used inthe first instance for power needs in the home(lighting, household a

Pagina 78

Navigation and changing parametersCalling up the main menuPress the menu key until the menu items "Informa-tion", "Settings" and &

Pagina 79 - Using the PV power surplus

7.3 Systems with aphotovoltaic plant SystemsThe smart heating function can be used with thefollowing variants:n Hybrid heat pumpn Split air/water h

Pagina 80

8 Index CChanging parameters... 8Connection of the controller to the electricitymeters and inverter...

Pagina 81

REMKO Smart WP MANAGER 82

Pagina 83

ConsultingThanks to intensive training, our consultants are always completely up-to-date in terms of technical knowledge. This has given us the reputa

Pagina 84 - REMKO INTERNATIONAL

Select "Change" (right softkey). The select valueappears marked in blue.Language / TimeTime: 14 : 54Cancel2/7NextFig. 9: Selecting a parame

Comentarios a estos manuales