Hydraulic diagram for heat pump assembly WKF Frankfurt
Functions: heating and hot water, operating mode: monoenergetic or bivalent alternative. Solar prepared.
Integration of solid fuels possible.
The operating mode here can only be monoenergetic or bivalent alternative!
Fig. 88: Example hydraulic diagram for HP assembly WKF Frankfurt
A1: Outdoor unit 1
A2: Outdoor unit 2 (WKF Duo)
B: Indoor unit (WKF/WKF Duo)
C: Storage tank
D: Second heat generator
E: Cooling cycle
F1-2: Mixed heating cycle (WKF)
F1-4: Mixed heating cycle (WKF Duo)
Menu item Parameter Factory setting WKF
WKF
Duo
Control panel address Control panel 1-3 Control panel 1 X X
Country Deutschland - Slovensko Deutschland X X
Load setting Accept the parameters Saving process X X
Language Deutsch - Polski Deutsch X X
Time zone Var. time zones possible Winter + 1(CET) X X
Date setting Year / Month / Day Basic settings X X
Time setting Hours / Minutes Basic settings X X
Activate heat pump Activated / Deactivated Activated X X