Software update
When first installing the controller this parameter is
confirmed with "NO".
If a new software status is installed after the initial
installation, it is possible to confirm this with "YES"
and all existing parameters will be accepted anew.
This means a complete new installation is unnec-
essary.
Fig. 37: Software update
Activating the heat pump
The controller detects automatically that a heat
pump has been connected. If necessary, activate
the heat pump (select with the rotary knob and
confirm with "OK").
Fig. 38: Activating the heat pump
Menu item Parameter Factory setting
Activating
the heat
pump
Activated
Activated
Deactivated
Press "Next".
Selecting the operating mode
Fig. 39: Bivalent alternative operating mode
Fig. 40: Monoenergetic operating mode
Menu item Parameter Factory setting
Operating
mode selec-
tion
Monoenergetic
Monoenergetic
Bivalent alterna-
tive
Selection of the auxiliary heat generator:
- Bivalent alternative (heat pump or oil/gas-fired
boiler or wall heating)
- Monoenergetic (heat pump and/or Smart Serv
electric heating element) according to usable limits
31