Operating manual
Read the instructions prior to performing any task!
REMKO Smart WP-MANAGER
Smart-Control for WKF/WKF-compact 85/120/180
Quick manual for users
0037-2013-01 Edition 1, en_GB
Vista de pagina 0
1 2 3 4 5 6 ... 35 36

Indice de contenidos

Pagina 1 - Operating manual

Operating manualRead the instructions prior to performing any task!REMKO Smart WP-MANAGERSmart-Control for WKF/WKF-compact 85/120/180Quick manual for

Pagina 2 - Made by REMKO

2.2 Menu structure of the con-troller The following information is primarily directed atsystem operators. Specialists can find relevantadditional i

Pagina 3 - Table of contents

Overview of the menus (User level)LEVEL 03D houseHot waterRoom climateLEVEL 1Information Settings MessagesLEVEL 2BasicinformationSolarBasicsettingsSol

Pagina 4

"3D house" animationOnce the Smart Control commissioning wizard hasbeen completed, you will see the home screen withthe 3D house. Pressing t

Pagina 5

Explanation of operating modes:Standby - the controller waits for the next requestDispensing operation - hot water is being dis-pensedCirculation - ci

Pagina 6

Favourites menu: for the userUsing the rotary knob (turning it clockwise) you canaccess other views. They allow you to rapidly andeasily adjust the mo

Pagina 7 - Operation

One-off hot water / party modeActivating Party mode (select with the rightsoftkey) causes the next window of time withreduced heating to be disregarde

Pagina 8

CO2 savingsCO2 savings specifies how much CO2 emissionshave been avoided. The calculation of CO2 savingsis based on the amount of renewable energy gen

Pagina 9 - Next viewStart animation

"Information" menu item - UserThis menu contains information about the current operating status of the system. The menu is opened withthe

Pagina 10 - REMKO Smart WP-MANAGER

"Information" menu item (continued) - UserLevel 2menu itemLevel 3 menu item InfoSolarPump A01 / Pump control signal A40If a solar plant is

Pagina 11 - Aditional

"Information" menu item (continued) - UserLevel 2menu itemLevel 3 menu item InfoFloorheating cycleAbs.prim. pump speed A41Level for the te

Pagina 12

Made by REMKOTranslation of the original operating manualRead these operating instructions carefully before commis-sioning / using this device!These

Pagina 13

"Information" menu item (continued) - UserLevel 2menu itemLevel 3 menu item InfoHeat pumpHeat pump statusLevel for the temperature display

Pagina 14

"Settings" menu item - UserIn this menu you can configure the settings. For example, you can adjust hot water and heating tempera-tures or

Pagina 15 - Time period

"Settings" menu item (continued) - UserLevel 2menu itemLevel 3 menu item Level 4 menu item InfoHeating /coolingModeRoom climate modeParame

Pagina 16

"Settings" menu item (continued) - UserLevel 2menu itemLevel 3 menu item Level 4 menu item InfoFloorheating cycleTime programme A Level f

Pagina 17

2.3 Switching times of the heating cycles Heating cycle underfloor - switching timesDescription Value range Factory setting Heating modeTime progra

Pagina 18

Heating cycle radiator - switching timesDescription Value range Factory setting Heating modeTime programm A Mon-Sun Mon-Sun 0:00-24:00Time programm B

Pagina 19

Heating cycloe hot water - switching timesDescription Value range Factory setting Heating modeTime programm A Mon-Sun Mon-Sun 0:00-24:00Time programm

Pagina 20

3 Installation 3.1 Room installation of theSmart-Control NOTICE!Only use the unit in dry areas and protect itfrom electromagnetic radiation.The

Pagina 21

4 Electrical wiring 4.1 Structure electrical connection I/0 module Cable cross-sections corresponding to the supplied connection cable!Place the

Pagina 22

4.2 Terminal assignment / legend Terminal assignmentTerminal Input Output Signal Connection layoutPW X Power supply I/O 230VPP X Power supp

Pagina 23

Table of contents1 Safety and usage instructions...

Pagina 24

Terminal Input Output Signal Connection layoutA11 X Changeover valve 2. heat generatorA12 X Changeover valve solar / 2. storage tank poolA13

Pagina 25

5 PV power utilisation 5.1 Higher energy consumptionfrom the combination of heatpump and PV plant Ideal for new and existing photovoltaic plants

Pagina 26

5.2 Using the PV power surplus The self-generated photovoltaic power is used inthe first instance for power needs in the home(lighting, household a

Pagina 27 - Installation

5.3 Systems with aphotovoltaic plant SystemsThe smart heating function can be used with thefollowing variants:n Hybrid heat pumpn Split air/water h

Pagina 28

6 Index CChanging parameters... 8Connection of the controller to the electricitymeters and inverter...

Pagina 30

ConsultingThanks to intensive training, our consultants are always completely up-to-date in terms of technical knowledge. This has given us the reputa

Pagina 31 - PV power utilisation

1 Safety and usageinstructions 1.1 General safety notes Carefully read the operating manual before com-missioning the units for the first time.

Pagina 32

1.6 Safety notes for the operator The operational safety of the units and compo-nents is only assured providing they are used asintended and in a f

Pagina 33 - Systems with a

1.11 Transport and packaging The devices are supplied in a sturdy shipping con-tainer or inside the heat pump casing. Pleasecheck the equipment imm

Pagina 34

2 Operation 2.1 Design and functions Overview of the controls34546712 2Fig. 1: Controls of the Smart-Control1: SD card2: Movement indicator3: D

Pagina 35

Navigation and changing parametersCalling up the main menuPress the menu key until the menu items "Informa-tion", "Settings" and &

Pagina 36 - REMKO INTERNATIONAL

Select "Change" (right softkey). The select valueappears marked in blue.Language / TimeTime: 14 : 54Cancel2/7NextFig. 9: Selecting a parame